top of page

Extending range
without compromise

Available as a toric IOL

What is RayOne EMV?

An enhanced monofocal IOL delivering up to 1.5 D of high quality vision.

Up to 1.5 D¹ ⁴ ⁶ with an emmetropic target.

Increased range of focus

Truly non-diffractive IOL with monofocal levels of contrast sensitivity¹, dysphotopsia² ⁵ and high levels of patient satisfaction.³

High quality vision

Unique positive spherical aberration design provides a smoother transition between distance and near eyes.² 

Enhanced monovision

1.83° mean IOL rotation 3 to 6 months after surgery.⁸

Now available on the rotationally stable RayOne toric platform

Learn more about RayOne EMV

Preferred contact from local Rayner representative:

Learn more about RayOne EMV

Thank you for submitting your details, a member of the Rayner team will be in touch soon.

Please visit our main website to discover more about RayOne EMV:

Clinical results with RayOne EMV

Comparative outcomes with RayOne EMV

At the Hospital da Luz Lisboa in Lisbon, Professor Filomena Ribeiro and Professor Tiago Ferreira led a 150 patient double-arm, non-randomised prospective case series where RayOne EMV demonstrated excellent visual outcomes for distance and intermediate vision, and good visual acuity for near vision.¹

RayOne EMV versus TECNIS Eyhance

At the Hospital San Rafael in Madrid, 22 eyes of 11 patients were implanted with RayOne EMV and 70 eyes of 35 patients implanted with TECNIS Eyhance (Johnson & Johnson Vision). Bilateral emmetropia was targeted for all patients. The defocus curve reports the binocular vision obtained using the best distance correction.⁶

Monovision outcomes with RayOne EMV

At the Tan Tock Seng Hospital in Singapore, Dr Tun Kuan Yeo demonstrated the binocular impact of positive spherical aberration by combining RayOne EMV with 1.5 D of monovision. The study showed similar performance for both photopic and mesopic conditions.

graph-1.jpg
graph-2.jpg
graph-3.jpg
  1. Ferreira TB. Presented at ESCRS 2022.

  2. RayOne EMV: First Clinical Results, Rayner. Oct 2020.

  3. Rayner RayPRO, data on file.

  4. Rayner, data on file.

  5. Rayner Peer2Peer webinar. May 2022.

  6. Royo, M. RayOne EMV and TECNIS Eyhance: A Comparative Clinical Defocus Curve. Data on file. 2021.

  7. How to Choose the Right Solution for Your Patients, CRSTE April 2021.

  8. Bhogal-Bhamra GK, Sheppard AL, Kolli S, Wolffsohn JS. J Refract Surg. 2019;35(1):48-53.

How does RayOne EMV work?

how-it-works-emv-new-628x1024-1-1.png

Centre region

Induced positive spherical aberration.

Blended edge region

Reduced longitudinal spherical aberration designed to maintain visual acuity and constrast sensitivity under mesopic conditions.

Centre region

Induced positive spherical aberration.

Blended edge region

Reduced longitudinal spherical aberration designed to maintain visual acuity and constrast sensitivity under mesopic conditions.

With RayOne EMV Toric you can correct more of your patients, even those with significant corneal astigmatism

Proven rotational stability and centration⁸ with predictable, sustainable and accurate visual results

  • Average offset of only 0.08 mm 3 to 6 months after surgery⁸

  • 1.83° mean IOL rotation 3 to 6 months after surgery⁸

  • Available in a wide range of IOL plane cylinders: +0.75 D to +4.5 D, in +0.75 D increments

toric-image.jpg
distance-images-final-01.jpg

RayOne EMV

with positive spherical aberration

Standard Monofocal IOL

with zero spherical aberration

bottom of page